1029D
Status:
Aktiv Versendet - Nicht für neue designs empfohlen
Alternative:
Phasen:
1-Phasig
Steuermodi:
Phasenwinkel
Ausgang:
AC
Stromstärken:
50, 80, 120, 160, 200, 250, 300, 380, 425, 500, 600, 750, 1000
Spannung:
120, 240, 480, 575*
Steuerung:
Analog [de]
Feedbacktyp:
Voltage
Current
Power
External
Features:
Note: 1029D has superseded 1029C
- Line voltage compensation holds load voltage constant with changes in line voltage
- Soft-start for transformer loads.
- Missing cycle detection.
- Can be used with all load types.
- Thermostatically protected.
- Metering outputs representing both load current and load voltage.
- Compact and economical
- 2500 Vac RMS isolation between input/output and line voltage/heatsink.
- Natural convection and forced air cooled.
Command Signal:
0-5 VDC, 4-20 mA, or Potentiometer*
Applications:
Electric ovens, furnaces, kilns, transformer coupled loads, variable resistance loads and fast responding loads.
* Other special options are available; contact the factory for more information.
Grenzwerte:
Current limit
Warnungen:
Shorted SCR
Over current trip
Zulassungen:
UL
cUL/CSA