News

Jan 08, 2014 |
The FUSION Control Panel is provided free with all our micorprocessor-based controllers. This software allows you to conveniently monitor and adjust your controller settings. In 2014, we are releasing our controllers with Control Panel 3.5, which is required to run Version 5.0 firmware....
May 08, 2013 |
We've released a free whitepaper with information about Short Circuit Current Rating (SCCR) and its impact on meeting NEC 2005, Article 409 for Industrial Control Panels. We have also released two new web videos. In the first, "What is Short Circuit Current Rating (SCCR)?" Director of Sales Dan...
Apr 28, 2013 |
All FUSION and Compact FUSION units have been approved for cUL certification! Our controllers also have CE, RoHS, and 100 kA SCCR certification.  Learn more about FUSION and Compact FUSION here.
Apr 08, 2013 |
Have you seen our latest web video, "Improve Power Factor with Zero Cross Transformer Mode"? Click the link to hear a feature overview from Control Concepts President Cory Watkins. Our newest hybrid firing mode is producing excellent results in the field. Read more about ZCT Mode and download an...
Nov 26, 2012 |
Control Concepts has released a statement regarding the recent enactment of Congress HR 4173, specifically with regard to section 1502-Conflict Minerals.  Read our statement here.
Nov 16, 2012 |
Our engineers have compiled a list of the "Top 10 Costliest Mistakes In SCR Power Controller Design." This is our final addition to the series. Read the complete list, and contact us for more information. #1. Not having a mechanical disconnect SCRs are not mechanical disconnects...
Nov 10, 2012 |
Our engineers have compiled a list of the "Top 10 Costliest Mistakes In SCR Power Controller Design." Check back each week for two more entries in the series, and contact us for more information. #3. Not having a spare on hand While SCRs will give years of service if properly...
Nov 01, 2012 |
Our engineers have compiled a list of the "Top 10 Costliest Mistakes In SCR Power Controller Design." Check back each week for two more entries in the series, and contact us for more information. #5. FAILURE TO TEST ALL POSSIBLE FAULT AND ALARM RECOVERY SCENARIOS There is an...
Oct 25, 2012 |
Our engineers have compiled a list of the "Top 10 Costliest Mistakes In SCR Power Controller Design." Check back each week for two more entries in the series, and contact us for more information. #7. FAILURE TO MAINTAIN A MINIMUM LOAD An open load condition or too small of load can...
Oct 18, 2012 |
Our engineers have compiled a list of the "Top 10 Costliest Mistakes In SCR Power Controller Design." Check back each week for two more entries in the series, and contact us for more information. #9. REMOVING ENCLOSURE FILTERS / LEAVING ENCLOSURE DOORS OPEN Conductive dust, inside the...