More Information
You will need to login or register to access manuals and view product drawings. Adobe Reader is needed to view pdf files.
Options & Accessories
Fusing | 3-Pole Touchsafe Fusekit |
Fieldbus Options | Modbus TCP (Ethernet) |
PROFINET (Ethernet) | |
EtherNet/IP (Ethernet) | |
Options |
(Free with purchase)
|
Remote Display Kit | |
Remote Hand Terminal | |
USB Cable |
** 1-Pole Touchsafe Fusekit only recommended for line to neutral applications.
MicroFUSION Three Phase
Status:
Actively Shipping - Recommended for new designs
Phases:
Three phase
Firing mode:
Phase angle
Zero cross
Zero Cross Transformer Mode
Fast Zero Cross
Output:
AC
Amp Sizes:
8, 16, 32, 50, 80, 100, 130, 160, 200, 240, 320, 400
Voltage:
24-690 VAC (CE), 24-600 VAC (UL), 45-65 Hz
Control:
Analog
Digital
Feedback type:
Voltage
Current
Power
External
Features:
The controller features the following:
- Auto-ranging input voltage (CE: 24-690 VAC, UL: 24-600 VAC, 45-65 Hz)
- 16, 32, 50, 80, 100, 130, 160, 200, 240, 320, 400 Amp AC output (at 50° C, 6000 ft)
- Adjustable soft start
- UL, cUL, CE, RoHS, 100kA SCCR certifications
- 4-SCR and 6-SCR configurations
- Can be ordered as Delta Wye, 4-Wire Wye, and Inside Delta
- Missing cycle detection
- SYNC-GUARD and TRANS-GUARD
- Dedicated RUN/STOP bit
- Analog interface: up to two analog inputs, two retransmits
- Fieldbus options: EtherNet/IP, PROFINET, Modbus TCP
- Easy setup via Plug-n-Play USB
- Thermistor
- OEM options (consult factory)
MicroFUSION Three Phase Power Controller
MicroFUSION is available with one of two circuit boards. SX is a lower-cost alternative, whereas HX features CCI Link™ and is a fully populated board that can be field-upgraded to include retransmits and other features.
Available options include:
- General purpose input
- Second analog input channel (second setpoint, potentiometer input, external feedback, or pulse width modulation (PWM))
- Alarm relay (form C)
- 2 x 16 bit analog retransmits (0-10 VDC or 0/4-20 mA)
- Remote display (2-line, 16-character text display)
- High performance: True RMS power, load vontage feedback, load current feedback, high resolution control loop
- Increased accuracy, linearity
- Current limit
- External, touchsafe Class T Fusing
Retransmit:
Load voltage
Load current
Load power
Limits:
Voltage limit
Current limit
Power limit
Alarms:
Overtemp
Shorted SCR
Communications Loss
Current Limit
Open Load
Over current trip
Partial Load Fault
Power Limit
Voltage Limit
Phase loss
Agency approvals:
UL
CE
RohS
cUL/CSA
100 kA SCCR