More Information
You will need to login or register to access manuals and view product drawings. Adobe Reader is needed to view pdf files.
Options & Accessories
Fusing | 2-Pole Touchsafe Fusekit |
1-Pole Touchsafe Fusekit** | |
Options | Din Rail Mounting |
Potentiometer Kit |
** 1-Pole Touchsafe Fusekit only recommended for line to neutral applications.
1021A Single Phase Zero-Cross Power Controller
Status:
Actively Shipping - Not recommended for new designs
Phases:
Single phase
Firing mode:
Zero cross
Output:
AC
Amp Sizes:
10, 20, 30, 40, 70
Voltage:
120, 240, 480, 575*
Control:
Analog
Feedback type:
Voltage
Features:
- Line voltage compensation holds load voltage constant with changes in line voltage
- Compact and economical
- Fast cycling distributive control improves heater life and reduces temperature variations.
- 2500 Vac RMS isolation between input/output and line voltage/heatsink.
- Natural convection.
Command Signal:
0-5 VDC, 0-10 VDC, or potentiometer.*
Alternate phases:
Available in three phase as a 3021A.
Applications:
Electric ovens, furnaces and kilns. An excellent contactor replacement and may be used in all resistive heating applications.
Notes:
Even greater density can be achieved by using the 1021A on our 1600 family heatsink. Up to twelve 70 amp controllers, all within a 7.28" x 14.5" footprint!
* Other special options are available; contact the factory for more information.
Agency approvals:
UL
cUL/CSA