Model | Phases | Firing Mode | Output | Voltage | Current Low | Current High | Highlights |
---|---|---|---|---|---|---|---|
MicroFUSION Three Phase | Three phase | Phase angle, Zero cross, Zero Cross Transformer Mode, Fast Zero Cross | AC | 24-690 VAC (CE), 24-600 VAC (UL), 45-65 Hz | 8 | 400 |
MicroFUSION is an ultra-compact high performance digital SCR controller that adapts to the analog environment as well as the digital environment. |
FUSION Three Phase (AC) Power Controller 500 - 1200A | Three phase | Phase angle, Zero cross, Fast Zero Cross | AC | Auto-Ranging Line Voltage 24-600 VAC, 45-65 Hz | 500 | 1 200 |
24 - 600 Vac. A microprocessor-based SCR controller operating both analog and digital interfaces. A phase angle or zero cross fired SCR controller which linearly controls, with respect to the setpoint, the AC voltage, current, or true power applied to a three phase electrical load. The 3 phase controller can be ordered in either 2 or 3 leg control with 2 leg being limited to zero cross firing. Control is achieved for 3 leg by three pairs of inverse parallel SCRs or in 2 leg by 2 pairs of inverse parallel SCRs. |
FUSION Single Phase (DC) Power Controller | Single phase | Phase angle | DC | Auto-Ranging Line Voltage 24-600 VAC, 45-65 Hz | 45 | 1 080 |
24 - 600 Vac. A microprocessor-based DC SCR controller operating both analog and digital interfaces. A phase angle fired controller which linearly controls, with respect to the setpoint, the DC voltage, current, or true power applied to an electrical load. Control is achieved by means of a half controlled SCR bridge. |
FUSION Three Phase (DC) Power Controller | Three phase | Phase angle | DC | Auto-Ranging Line Voltage 24-600 VAC, 45-65 Hz* | 60 | 1 400 |
24 - 600 Vac. A microprocessor-based DC SCR controller operating both analog and digital interfaces. A phase angle-fired controller which linearly controls, with respect to the setpoint, the DC voltage, current, or true power applied to an electrical load. Control is achieved by means of a six SCR bridge with freewheeling diode. |
FUSION Single Phase (AC) Power Controller 500 - 1200A | Single phase | Phase angle, Zero cross, Fast Zero Cross | AC | Auto-Ranging Line Voltage 24-600 VAC, 45-65 Hz | 500 | 1 200 |
24 - 600 Vac. A microprocessor-based SCR controller operating both analog and digital interfaces. A phase angle or zero cross fired controller which linearly controls, with respect to the setpoint, the AC voltage, current, or true power applied to an electrical load. Control is achieved by means of a pair of inverse parallel SCRs. |